Product Handbook 2026 - Volume 1

Control systems Safety valves

4

Table 1 - SV615 flow capacity for saturated steam in kilogrammes per hour (kg/h) (calculated in accordance with EN ISO 4126:2004 at 5% overpressure) Derated coefficient of discharge (Kdr) = 0.71

Valve size DN in/out

15/20

20/32

25/40

32/50

40/65

50/80

Flow area (mm 2 )

113

314

452

661

1 075

1 662

Set pressure (bar g)

Flow capacity for dry saturated steam kg/h

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5

68

188

271

396

644

996

90

250

360

527

857

1324

112

312

449

656

1067

1650

134

373

537

785

1276

1973

156

434

624

913

1485

2295

178

494

712

1040

1692

2616

200

555

799

1168

1899

2936

221

615

885

1295

2106

3256

243

675

972

1422

2312

3574

265

735

1058

1548

2517

3892

286

795

1144

1674

2722

4208

4.7 33

308

855

1230

1799

2926

4524

329

914

1316

1925

3130

4839

350

974

1402

2050

3334

5154

372

1033

1487

2175

3537

5468

393

1092

1573

2300

3740

5783

414

1152

1658

2425

3943

6096

436

1211

1743

2549

4146

6410

457

1270

1828

2674

4348

6723

10.0

478

1329

1913

2798

4551

7036

11.0

521

1447

2084

3047

4955

7661

12.0 13.0 14.0 15.0 16.0 17.0 18.0

563

1565

2253

3295

5359

8286

606

1683

2423

3544

5763

8910

648

1801

2593

3792

691

1919

2762

4040

733

2037

2932

4288

775

2155

3101

4535

818

2272

3271

4783

TI-P316-01 CTLS Issue 20

Page 5 of 10

SV615 Safety Valve

Powered by