Control systems Desuperheaters

4

2. Spray type desuperheater (STD) A complete Desuperheater ready for installation, including spray nozzle, nozzle housing, thermal sleeve and flanged shell.

Thermal sleeve

Desuperheated steam

Superheated steam

Spray nozzle assembly

Cooling water

4.8 3

Standard STD has welded spray nozzle assembly. Item shown above is STD with removable spray nozzle.

Applications: - Relatively constant load handling duties. - Dumping steam application. - Control of downstream temperature not critical.

Mechanical design temperature and flange rating <371 °C (<700 °F)

ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Slip-on (Weld neck optional)

371 - 427 °C (700 - 800 °F) 424 - 570 °C (795 - 1058 °F)

ASME 150, ASME 300, ASME 600 + PN16, PN25, PN40 Weld neck (Slip-on N/A)

ASME 150, ASME 300, ASME 600, ASME 900, ASME 1500 Weld neck (Slip-on N/A)

Materials

Mechanical design temperature up to and including 427 °C (800 °F)

Mechanical design temperature above 427 °C (800 °F) up to and including 570 °C (1058 °F)

Component

Shell

ASTM A106 Grade B

ASTM A335 P11

Water branch

ASTM A106 Grade B

ASTM A335 P11

Flanges

ASTM A105N

ASTM A182 F11

Spray nozzle

ASTM A182 F316L

ASTM A182 F11

Nozzle holder

ASTM A350 LF2N

ASTM A182 F11

Thermal sleeve

ASTM A312 TP316L

ASTM A335 P11