Product Handbook 2026 - Volume 1

Compressed air products Regulators

5

Capacities For safety valve sizing purposes the full lift capacity for the MR1M and MR2M is 0.21 KVS.

Performance (with primary pressure 10 bar)

Air flow scfm

5.2 4

Air flow dm 3 /s

9.2.5

Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P504-10) supplied with the product. Installation note

The regulator should be sited as close as possible to the equipment it is serving. Connect the regulator so that air flow is in the direction shown by the arrow on the body. A pressure gauge (supplied as an accessory, when ordered) fitted to one of the gauge ports is recommended to show the secondary pressure. A filter should be installed in front of the regulator to keep dirt out. Panel mounting the MR2M The panel must not exceed 8 mm thick. The required hole is 31 mm. How to order Example: 1 off MR1M Monnier miniature compressed air regulator having ¼" screwed BSP connections and a 0.2 to 2 bar control spring. Note: The MR1M or MR2M regulator will be supplied with a 0.7 to 9 bar spring as standard.

TI-P504-09 CH Issue 2

Page 4 of 4

MR1M, MRN1M and MR2M Monnier Miniature Compressed Air Regulators

Powered by