Compressed air products Filter/regulators
5
Capacities The full lift capacities for safety valve sizing purposes is 0.21 Kvs.
Performance selection (with primary pressure 10 bar) For any specified primary filtration pressure, there is a maximum recommended air flowrate. Keeping within this, will ensure that the element performance maintains the stated high efficiency levels.
Air flow scfm
5.4 4
Air flow dm 3 /s
9.4.3
The graph utilises some typical values for secondary flow/pressure to demonstrate droop
Pressure droop
Droop =
@ Relevant flowrate
Set point
TI-P504-05 CH Issue 2
Page 4 of 6
MP2M and MPN2M Monnier Miniature Compressed Air Filter/Regulators