Product Handbook 2026 - Volume 1

Compressed air products Filter/regulators

5

Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P504-06) supplied with the product. Warning

Polycarbonate bowls are attacked by phosphate ester fluids, solvents, paint thinners and carbon tetrachloride. These and similar substances should never be allowed to come into contact with the bowl. Certain compressor lubricating oils also contains additives harmful to polycarbonate and, where there is any doubt we recommend, in the interests of safety, that a bowl guard be fitted. Installation note Fit in a horizontal pipe, with the bowl vertically downwards, as close as possible to the equipment it is serving. Connect the unit so that the air flow is in the direction shown by the arrow cast on the body. A pressure guage fitted to one of the ports is recommended (to show the secondary pressure). The port(s) not in use should be blanked off with the plugs supplied. Panel mounting The panel must not exceed 8 mm thick. The required hole is 31 mm diameter. How to order Please state quantity, size and type and any options which are required. Unless otherwise stated, the filter/regulator will be supplied with the 0.7 - 9.0 bar g control spring and a polycarbonate bowl with drain. Example: 1 off MP2M Monnier self-relieving miniature compressed air filter / regulator having a 0.2 - 2.0 bar g control spring and ¼" BSP connections. 1 off Bowl guard.

5.4 5

9.4.4

TI-P504-05 CH Issue 2

Page 5 of 6

MP2M and MPN2M Monnier Miniature Compressed Air Filter/Regulators

Powered by