Product Handbook 2026 - Volume 1

Compressed air products Isolation valves, drain traps and ancillaries

5

Pressure/temperature limits

A

B C A

220 200 150 100 50 0 0 2 4 6 8 10121416 C A B

Pressure bar g

The product must not be used in this region.

A-A-A Flanged BS 4504 PN16. A-B-B Flanged ANSI B 16.1/BS 1560 class 125 having flat faces. A-C-C Flanged JIS/KS 10.

Body design conditions

PN16

PMA Maximum allowable pressure

16 bar g

TMA Maximum allowable temperature

220 °C

Minimum operating temperature

0 °C

Product is safe for use under full vacuum conditions Designed for a maximum cold hydraulic test pressure of

24 bar g

5.5 33

Where the trap is to handle a liquid having a specific gravity of less than 1, the following maximum differential pressures will apply.

Specific gravity

Trap

1.0

0.9 0.6 Maximum differential pressure bar 0.8 0.7

CA14S-4.5 CA14S-10 CA14S-14

4.5

4.5

4.5

3.4

2.0

10.0

9.5

6.8

5.5

3.4

14.0 14.0 11.0

8.0

5.0

9.5.28

TI-P148-35 CMGT Issue 5

Page 3 of 6

CA14S Air and Gas Trap DN40 and DN50 (Flanged)