Product Handbook 2026 - Volume 1

Performance of the units (kg/h) Heat transfer solutions Clean steam generators

6

Clean steam pressure (bar g)

Plant steam pressure (bar g)

8**

7

6

5

10.8

1250

1280

1190

1100

10.2

1050

1280

1190

1100

CSG-FBHP-130

9.6

-

1280

1190

1100

8.2

-

-

1190

1100

7.1

-

-

-

1100

10.8

1800

1790

1670

1530

10.2

1550

1790

1670

1530

CSG-FBHP-185

9.5

-

1790

1670

1530

8.1

-

-

1670

1530

7

-

-

-

1530

10.8

2200

2230

2090

1920

10.2

1900

2230

2090

1920

CSG-FBHP-235

9.3

-

2230

2090

1920

8

-

-

2090

1920

6.8

-

-

-

1920

10.8

2900

2870

2680

2460

10.2

2500

2870

2680

2460

6.1 24

CSG-FBHP-300

9.6

-

2870

2680

2460

8.2

-

-

2680*

2460

7.1

-

-

-

2460

10.8

3500

3570

3340

3070

10.2

3000

3570

3340

3070

CSG-FBHP-375

9.4

-

3570

3340

3070

8

-

-

3340

3070

6.9

-

-

-

3070

10.8

4400

4460

4170

3830

10.2

3700

4460

4170

3830

CSG-FBHP-470

9.6

-

4460

4170

3830

8.2

-

-

4170

3830

7.1

-

-

-

3830

10.8

5300

5740

5360

4930

10.2

4350

5740

5360

4930

CSG-FBHP-600

9.9

-

5740

5360

4930

8.6

-

-

5360

4930

7.5

-

-

-

4930

Note: Plant steam pressure must be sufficiently greater than clean steam pressure for clean steam production ** 8 bar g clean steam flowrates have been limited due to supply pressure. Higher capacity units can be considered as a bespoke.

TI-P664-05 TES Issue 6

Page 4 of 10

CSG-FBHP High pressure clean steam generation system for Food & Beverage

Powered by