Product Handbook 2026 - Volume 1

Heat transfer solutions Thermocompressors

6

Control The compression ratio is 2.25 (see the example on page 4 that illustrates how to calculate the compression ratio) so the SJT Steam Jet Thermocompressor will be 'Sonic'. Therefore the calculated Motive (HP) steam flowrate must be fixed. The SJT Steam Jet Thermocompressor is designed for a Suction flowrate of 1 500 kg/h. Without control, if the Suction (LP) steam flowrate falls, the SJT will try and suck harder and the Suction pressure will begin to fall. Consequently, in this application, we can install a simple 'recycle' loop. This recycles some discharge steam back to the suction. By maintaining the Suction flow, the SJT operates at its design point which keeps the Suction pressure constant.

Typical application drawings:

Motive steam

Steam line

To process

Flash

Process heat exchanger

Flash vessel

Condensate line

Condensate pump

Typical SJT Steam Jet Thermocompressor application

6.3 10

Motive steam

Make-up steam valve

Flash blow through

Drying cylinder



Condensate line

Separator

Condensate pumped back to feedwater tank

Typical Paper Mill application

TI-P493-02 TES Issue 3

Page 10 of 11

SJT Steam Jet Thermocompressor

Powered by