Product Handbook 2026 - Volume 1

General information Product limitations

7

 

E Sometimes end connections or internal components may restrict the operating envelope of the product below the standard rating. Care must therefore be taken in selecting appropriate end connections . In this case the product should not be used in area 'e' and will be worded:



E

The product should not be used in this region because...(the actual reason will depend on the product being described).















Pressure bar g

  

F If a product should not be used above a certain temperature, or an ancillary product is required to operate above a certain limit then it will be tinted and worded appropriately. e.g.:

F

High temperature bolting required for use in this region (the actual reason will depend on the product being described).

















Pressure bar g

An example of a finished diagram:

A

  

2

1

Steam saturation curve

4

5



3

C

B















Pressure bar g

1

The product must not be used in this region.

2 3

High temperature bolting is required for use in this region.

7.4 6

The product should not be used in this region or beyond its operating range as damage to the internals may occur.

4 A - C Flanged end connections EN 1092 PN16.

5 A - B Flanged end connections EN 1092 PN25 or ANSI B 16.5 Class 300.

11.4.7

TI-S24-41 CH Issue 3

Page 2 of 5

Pressure / Temperature Limits for Control Valves

Powered by