Product Handbook 2026 - Volume 1

General information Useful calculation data

7

How to use the chart Example 2: How to find the K v value for a non-critical flow application. Steam demand of heat exchanger = 230 kg/h. Steam pressure upstream of valve = 5 bar g = 6 bar a Steam pressure required in exchanger = 4 bar g = 5 bar a Using the selection chart: Draw horizontal lines from 230 kg/h, and from 6 bar a to pressure drop of (6 - 5 = 1 bar). Drop a vertical line from the intersection to meet the 230 kg/h horizontal. Read the K v at this crossing point, i.e. K v = 4.

Example 2

7.5 11

Example 2

11.5.8

TI-GCM-08 CM Issue 2

Page 3 of 5

Saturated Steam Sizing Chart