Product Handbook 2026 - Volume 1

General information Useful calculation data

7

How to use the chart Example 3: How to find the pressure drop across a valve with a known K v . Steam demand of heat exchanger = 3 000 kg/h Steam pressure upstream of valve = 10 bar g = 11 bar a K v of valve to be used = 40 Using the selection chart: Draw horizontal lines from 11 bar a, and from 3 000 kg/h to meet K v = 40 line. Draw a vertical line upwards from the intersection to meet the 11 bar a horizontal. Read the pressure drop at this crossing point, i.e. ∆ P = 1 bar (approximately).

Example 3

7.5 12

11.5.9

Example 3

TI-GCM-08 CM Issue 2

Page 4 of 5

Saturated Steam Sizing Chart