Boiler house Conductivity sensors
2
Dimensions (approximate) in millimetres
98
60 A / F
CP10 sensor shown with PT2 plug tail fitted
Standard length 1 250
120
*
1 250
TP20 temperature sensor
2.5 2
* ¼" BSP sample connection
Bore Ø35 1¼" BSP or Bore Ø26 1" NPT
Weight 1.9 kg
Maintenance The equipment requires no specific maintenance other than periodic inspection and cleaning as described in the Installation and Maintenance Instructions.
How to specify In-line sensor chamber with conductivity and temperature sensors.
Safety information This document does not contain enough information to install the product safely. Refer to the Installation and Maintenance Instructions provided with the product. The CP10 sensor contains PTFE which can give off toxic fumes if exposed to excessive heat.
Installation Caution: Do not install the sensor outdoors without additional weather protection.
The sensor chamber may be fitted in a vertical or horizontal pipeline with suitable isolation valves to allow inspection/cleaning of the sensors. Reducers may be fitted if required. Flow can be in either direction. The sensors themselves must be horizontal. For full information see the Installation and Maintenance Instructions. Caution: Ensure the PT2 wire is not exposed to a temperature greater than 120 °C.
How to order Example : 1 off Spirax Sarco S20 sensor chamber complete with CP10 sensor, PT2 plug tail, ¼" BSP blanking plug, and TP20 temperature sensor.
TI-P403-45 AB Issue 6
S20 Sensor Chamber and Sensors