Boiler house Heat recovery systems
2
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. © Copyright 2014
AI-P404-12 AB Issue 3
Sizing a Flash Vessel on up to Three Trap Pressures
2.8 17
Model FV15 and FV18 shown
Pages 2 and 3 Shows an example considering condensate from three steam systems at different pressures, 20 bar g, 10 bar g and 6 bar g, discharging into a flash vessel designed to operate at 2 bar g. Pages 4 and 5 Shows the full table for flash vessel sizing.
AI-P404-12 AB Issue 3
Page 1 of 5
Sizing A Flash Vessel On Up To Three Trap Pressures
Powered by FlippingBook