Product Handbook 2026 - Volume 1

Boiler house Bottom blowdown systems

2

BBV selection guide:

Valve series

BBV

BBV = Boiler blowdown valve

4 = Carbon steel

Body material

4

6 = Stainless steel

1 = Screwed

Connections

3

3 = Flanged

P = PTFE

Stem sealing

P

H = Graphite

2.11 11

Seating

W

W = Stellite

Type of trim

S

S = Standard trim

Trim balancing

U

U = Unbalanced

Bonnet type

S

S = Standard

Bolting

S

S = Standard

= DN15, DN20, DN25, DN32, DN40 and DN50 ½", ¾", 1", 1¼", 1½" and 2"

Valve size

DN20

EN standard = Flanged EN 1092 PN40

Connections For alternative

PN40

connections to those stated please contact Spirax Sarco.

ASME standard = Flanged ASME 150 and ASME 300

PN/M = Air pneumatically actuated supplied with a manual actuation lever

Version

PN/M

M = Manually actuated complete with a manual actuation lever

Selection example:

BBV 4

3

P

W S

U S

S DN20 PN40 PN/M

How to order example: 1 off Spirax Sarco BBV43PWSUSS DN20 PN/M

TI-P405-51 EMM Issue 6

Page 11 of 11

BBV Automatic or Manually Actuated Boiler Blowdown Valves DN15 to DN50