UK Product Handbook 2026 - Volume 1

Flowmetering Gilflo and ILVA flowmeters 3

Standards This flowmeter complies with the requirements of the EU Pressure Equipment Directive 2014/68/EU carries the

marks and falls

within the following PED categories:

Group 1 Gases

Group 2 Gases

Group 1 Liquids

Group 2 Liquids

Product

DN150 - DN200

3 3

3 3

2 2

SEP

ILVA20

DN250 - DN300

1

IP rating

IP65 with correct cable glands

Electromagnetic Compatibility Directive

2014/30/EU

UK Electromagnetic Compatibility Regulations 2016 Calibration

ISO 17025

Designed to ASME BPVC section V111

EN61010-1:2010 UL/CSA 61010-1:2012 (third edition)

Safety requirement for electrical equipment for measurement, control, and laboratory use

3.2 22

IP Testing

EN60529:1992/A2:2013

Electromagnetic Compatibility – Emissions and Immunity

EN 61326-2-3:2013

Sine Vibration Sequence Transportation Vibration

EN61298-3:2008 Section 7

EN60068-2-6:2008

Certification This product is available with certification to EN 10204 3.1. Note: All certification/inspection requirements must be stated at the time of order placement.

Sizes and pipe connections Available in DN150, DN200, DN250 and DN300 (6", 8", 10" and 12") pipeline sizes. This flowmeter is a wafer design suitable for fitting between the following flanges:

- EN 1092-1 PN16, PN25 and PN40 - ASME B 16.5 Class 150 and 300 - Japanese Industrial Standard JIS 20 - Korean Standard KS 20 Note: The Spirax Sarco flowmeter should be installed in pipework manufactured to BS 1600, ASME B 36.10 Schedule 40 or EN 10216-2/EN10216-5 equivalent.

Materials Flowmeter body

Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel

Internals

316

2 way manifold 3 way manifold

1.4408 CF8M

316L

Impulse hoses (Not included) *

MVT housing

Aluminium

Copper free aluminium, max 0.5 mg

Pressure sensor

Stainless steel Inconel X750

Spring

* Stainless steel Flexi Hose (1 and 2 metre) pipes are supplied separately.

TI-P337-70 EMM Issue 10

Page 2 of 7

ILVA20 Flowmeter and MVT10 Differential Pressure Transmitter for Saturated and Superheated Steam Service

Powered by