Product Handbook 2026 - Volume 1

Flowmetering Gilflo and ILVA flowmeters 3

Performance The Flowmeter is a calibrated system and consists of two parts, the ILVA20 (pipeline element) and the MVT10 (differential pressure transmitter) that includes the electronics, display and static pressure transmitter. The MVT10 flowmeter has inbuilt electronics which give a density compensated output. An LCD display is incorporated within the electronics head. The M750 display unit can be used to provide a remote display function if required, utilising the 4 - 20 mA output. ±2% of measured value from 12% to 100% of maximum rated flow. ±0.5 %FSD from 2%-12% of flow.

Turndown

50:1 typical

Flowmeter sizing

To view the sizing suite, please go to http://prs.spiraxsarco.com/sizingsuite.

kg/h (lbs)

0.6 (8)

1 (15)

3 (44)

5 (73)

7 (102)

10 (145)

12 (174)

15 (218)

20 (290)

25 (363)

30 (435)

32 (464)

Flow

Pressure bar g (psi g)

3.2 24

5386 (11874)

5981 (13836)

8301 (18301)

10071 (22203)

11562 (25490)

13487 (29734)

14631 (31661)

16200 (35715)

18538 (40869)

20639 (45501)

22573 (49765)

23311 (51392)

Max

DN150 (6")

108 (238)

120 (265)

166 (366)

201 (443)

231 (509)

270 (595)

293 (646)

324 (714)

371 (818)

413 (911)

451 (994)

466 (1027)

Min

10586 (23338)

11757 (25920)

16317 (35973)

19795 (43641)

22726 (50102)

26509 (58442)

28757 (63398)

31840 (70195)

36437 (80330)

40566 (89433)

44368 (97815)

45817 (101009)

Max

DN200 (8")

212 (467)

235 (518)

326 (719)

396 (814)

455 (873)

530 (1003)

575 (1168)

637 (1268)

729 (1404)

811 (1607)

887 (1788)

916 (2019)

Min

14393 (31731)

15985 (35241)

22185 (48910)

26915 (59337)

30899 (68099)

36043 (79461)

39099 (86199)

43292 (95443)

49541 (109219)

55156 (121598)

60325 (132994)

62295 (137337)

Max

DN250 (10")

288 (635)

320 (705)

444 (979)

538 (1186)

618 (1362)

721 (1590)

782 (1724)

866 (1909)

991 (2185)

1103 (2432)

1206 (2659)

1246 (2847)

Min

20382 (44935)

22637 (49311)

31417 (69263)

38115 (84029)

43758 (96470)

51042 (112528)

55369 (122068)

61307 (135159)

70157 (154670)

78107 (172197)

85428 (188337)

88218 (194488)

Max

DN300 (12")

408 (899)

453 (999)

628 (1385)

762 (1679)

875 (1929)

1021 (2251)

1107 (2441)

1226 (2703)

1403 (3093)

1562 (3364)

1709 (3768)

1764 (3889)

Min

TI-P337-70 EMM Issue 9

Page 4 of 7

ILVA20 Flowmeter and MVT10 Differential Pressure Transmitter for Saturated and Superheated Steam Service

Powered by