Flowmetering Target flowmeters 3
Technical data IP rating
IP65 with correct cable glands
Loop powered with optional RS485: 24VDC
Power supply
4-20mA (not available with RS485 option) Pulsed output (V max 28 Vdc R min 10 k W ) Modbus EIA 232C (RS 232C) with optional RS485: EIA 485 (RS 485C)
Outputs
Communication port
Dimensions/weights (approximate) in mm and kg
A
Note: Dimension ' X ' is a recommended minimum distance between the pressure tapping and the flowmeter. However it can be installed at any distance provided the cable allows (Standard cable length is 1 m).
X
D
F
3.3 4
G
C
E
Size
A Flowmeter OD
C
D
E
F
G X
Weight TVA Superheat kit
'U' syphon
DN50 DN80 DN100
35
103
322
125
65
250
160
300
2.67
0.3
0.5
45
138
334
115
65
270
160
300
4.38
0.3
0.5
60
162
344
155
65
280
160
300
7.28
0.3
0.5
TI-P192-01 MI Issue 4
Page 4 of 6
TVA Flowmeter for Saturated and Superheated Steam Service