Section B: Pipeline details Flowmetering Orifice plate flowmeters
3
Value
Units
Nominal line size Line inside diameter Line schedule (if known)
N/A
Flange specification
N/A
Number of straight pipe diameters available upstream
N/A
Number of straight pipe diameters available downstream
N/A
Pipe material
N/A
Please provide a sketch showing all details of pipework including any valves, bends, fittings etc. in the area where the M410 orifice plate is to be fitted. This is important as the performance of all orifice plates can be affected greatly by installation factors. Using the information from sections A and B, Spirax Sarco will size the correct orifice plate in line with the parameters laid down in BS 1042 / ISO 5167.
3.4 6
Section C: Options available The Spirax Sarco oriface plate flowmetering system is available in a number of options, at least one of which will suit the needs of a customer. Options 1 to 4 are for simple systems where automatic density compensation is not required. These are shown at the top of the next column...simply tick the option that meets your needs. Options for use with flowcomputers that DO NOT include density compensation: Option List of equipment in each package option 1 M410 orifice plate and gaskets 2 M410 orifice plate and gaskets, M610 DP transmitter
M410 orifice plate and gaskets with carrier ring, F50C isolation valves M410 orifice plate and gaskets with carrier ring, F50C isolation valves, M610 DP transmitter assembly
3
4
Option product code
Options 5 to 10 include equipment that allows automatic density compensation for maximum accuracy. These are shown below...simply tick the option that meets your needs. Options for use with flowcomputers that DO include density compensation: Option List of equipment in each package option 5 M410 orifice plate and gaskets, M610 DP transmitter assembly, EL2600 pressure transmitter 6 M410 orifice plate and gaskets, M610 DP transmitter assembly, EL2271 temperature transmitter
M410 orifice plate and gaskets, M610 DP transmitter assembly, EL2600 pressure transmitter, EL2271 temperature transmitter M410 orifice plate and gaskets with carrier ring, F50C isolation valves, M610 DP transmitter assembly, EL2600 pressure transmitter M410 orifice plate and gaskets with carrier ring, F50C isolation valves, M610 DP transmitter assembly, EL2271 temperature transmitter
7
8
9
M410 orifice plate and gaskets with carrier ring, F50C isolation valves, M610 DP transmitter assembly,
10
EL2600 pressure transmitter, EL2271 temperature transmitter
Option product code
Note: For all options, please state if a vent or drain hole is required in the M410 orifice plate.
TI-P176-04 MI Issue 7
Page 2 of 3
Orifice Plate Flowmeters Customer Data Sheet
Powered by FlippingBook