Flowmetering Turbine flowmeters 3
RIM20 range and benefits The RIM20-V delivers a direct reading of volumetric flowrate, generally the most cost-effective solution for liquid flow monitoring, in applications ranging from general water flows to hydrocarbon fuel flow measurement. The RIM20-VT integrates a precision 1 000 Ω platinum RTD temperature sensor that can be used to calculate and output a compensated mass reading. This device is typically used to measure flowrates of saturated steam. The RIM20-VTP offers you flow computer functionality in a compact field device. This multivariable instrument incorporates temperature and pressure sensors to provide an instantaneous reading of the compensated mass flowrate of gases, liquids and steam. In addition to outputs for totalized mass and alarm settings, the field-configurable electronics deliver up to three analogue 4 - 20 mA outputs of five process measurements, including volumetric flowrate, mass flowrate, pressure, temperature and density. The RIM20-EM Energy Monitoring option permits real-time calculation of energy consumption for a facility or process. The flowmeter can be programmed to measure steam, hot water or chilled water. The RIM20-VTP flowmeter monitors one side of the process, either sent or returned, and uses the input from a second separate temperature sensor on the opposite leg of the process to calculate the change in energy. Selectable energy units include BTUs, joules, calories, Watt-hours, Megawatt-hours and Horsepower-hours. The local or remote electronics indicate two temperatures, delta T, mass total and energy total.
Technical data
3.7 2
316L, 302, and 17-4PH, and 18-8 stainless steel, tungsten carbide, sapphire, plus: • DuPont Teflon ® based thread sealant on models with pressure transducer • DuPont Teflon ® packing on standard temperature models with packing gland • Graphite based packing on high temperature models with packing gland Any gas, liquid or steam compatible with 316L stainless steel and other listed wetted materials. Not recommended for multi-phase fluids S option - Standard -55 °C to +238 °C (-67 °F to +460 °F) *Where ATEX is required the lower temperature is further limited to -40 °C (-40 °F). H option - High -267 °C to +454 °C (-448 °F to +850 °F) *Where ATEX is required the lower temperature is further limited to -40 °C (-40 °F).
Wetted materials
Application
Temperature Process
Operating -40 °C to +60 °C (-40 °F to +140 °F) Storage -40 °C to +85 °C (-40 °F to +185 °F)
Temperature Ambient
Electrical Safety EN61010-1:2010 Overvoltage Category II Pollution Degree 2
LVD
Environmental
Emissions
Group 1, Class A (Suitable for Industrial Environments only)
EMC
Immunity
Suitable for Industrial Environments
Enclosure
NEMA 4X, IP66
Full-scale operating pressure
Maximum over-range pressure
2 bar a
30 psi a
4 bar a
60 psi a
7 bar a
100 psi a
14 bar a
200 psi a
Pressure transducer ratings
20 bar a
300 psi a
41 bar a
600 psi a
34 bar a
500 psi a
69 bar a
1 000 psi a
100 bar a
1 500 psi a
175 bar a
2 500 psi a
TI-P198-04 CMGT Issue 5