Product Handbook 2026 - Volume 1

Flowmetering Turbine flowmeters 3

Typical Metric flowrates Saturated steam (kg/h)

Nominal pipe size 80 mm 150 mm 200 mm 300 mm 400 mm 600 mm

Rotor

Pressure

Minimum

17

72

127

297

491

1 219

1.4 bar g

Maximum

225

929

1 642

3 817

6 270

15 367

Minimum

42

173

306

713

1 176

2 907

R40

5 bar g

Maximum

537

2 216

3 915

9 090

14 905

36 400

Minimum

75

310

549

1 279

2 106

5 194

10 bar g

Maximum

962

3 963

6 999

16 239

26 600

64 815

Minimum

20

82

146

341

563

1 396

1.4 bar g

Maximum

329

1 358

2 399

5 575

9 149

22 384

3.7 7

Minimum

48

198

350

817

1 347

3 328

R30

5 bar g

Maximum

785

3 237

5 716

13 265

21 735

52 993

Minimum

86

355

629

1 465

2 411

5 943

10 bar g

Maximum

1 405

5 786

10 215

23 687

38 771

94 337

Minimum

35

146

259

604

995

2 463

1.4 bar g

Maximum

530

2 187

3 863

8 968

14 704

35 898

Minimum

85

350

620

1 444

2 377

5 856

R20

5 bar g

Maximum

1 265

5 207

9 194

21 322

34 903

84 940

Minimum 152

628

1 111

2 586

4 252

10 448

10 bar g

Maximum

2 261

9 303

16 419

38 049

62 227

151 156

Minimum

61

253

448

1 045

1 721

4 247

1.4 bar g

Maximum

1 098

4 522

7 985

18 520

30 320

73 805

Minimum 147

606

1 072

2 496

4 103

10 082

R10

5 bar g

Maximum

2 615

10 755

18 979

43 967

71 883

174 497

Minimum 263

1 087

1 921

4 466

7 335

17 975

10 bar g

Maximum

4 672

19 197

33 862

78 386

128 050

310 382

Typical Imperial flowrates are on pages 9 and 10

TI-P198-04 CMGT Issue 5

Page 7 of 13

RIM20 Rotor Insertion Flowmeter

Powered by