Product Handbook 2026 - Volume 1

Flowmetering Turbine flowmeters 3

Typical Imperial flowrates Saturated steam (lb/h)

Nominal pipe size

Rotor

Pressure

3"

6"

8"

12"

16"

24"

Minimum

22

91

162

378

625

1 555

5 psi g

Maximum

287

1 187

2 098

4 883

8 029

19 727

Minimum 119

496

878

2 046

3 371

8 328

R40

100 psi g

Maximum

1 540

6 350

11 216

26 034

42 668

104 092

Minimum 220

913

1 615

3 761

6 191

15 249

200 psi g

Maximum

2 827

11 643

20 558

47 681

78 064

190 027

Minimum

25

105

186

434

717

1 782

5 psi g

Maximum

420

1 735

3 068

7 135

11 721

28 745

3.7 9

Minimum 137

568

1 006

2 344

3 861

9 530

R30

100 psi g

Maximum

2 251

9 272

16 373

37 984

62 207

151 526

Minimum 253

1 046

1 850

4 308

7 088

17 446

200 psi g

Maximum

4 129

16 994

29 996

69 532

113 761

276 542

Minimum

45

186

330

770

1 270

3 150

5 psi g

Maximum

677

2 797

4 943

11 485

18 849

46 119

Minimum 243

1 005

1 778

4 140

6 811

16 762

R20

100 psi g

Maximum

3 623

14 915

26 328

61 035

99 870

242 834

Minimum 447

1 848

3 268

7 601

12 492

30 657

200 psi g

Maximum

6 643

27 317

48 203

111 658

182 535

443 035

Minimum

78

323

572

1 334

2 199

5 440

5 psi g

Maximum

1 405

5 790

10 227

23 736

38 897

94 870

Minimum 421

1 739

3 075

7 153

11 755

28 849

R10

100 psi g

Maximum

7 490

30 791

54 325

125 807

205 605

498 759

Minimum 774

3 195

5 647

13 123

21 541

52 728

200 psi g

Maximum

13 719

56 341

99 362

229 926

375 467

909 528

Typical Metric flowrates are on pages 7 and 8

TI-P198-04 CMGT Issue 5

Page 9 of 13

RIM20 Rotor Insertion Flowmeter

Powered by