Product Handbook 2026 - Volume 1

Flowmetering Electromagnetic flowmeters 3

Dimensions / weights (approximate in mm and kg)

205

115

108

A

158

D

L

M20 x 1.5

DN

Dimensions

Size

Weight *

D

A

L

DN25

1"

72

158 104

2

3.8 2

DN32

1¼"

82

168 124

2

PN40 and ASME 300

DN40 DN50 DN65 DN80

1½"

92

179 124

2

2"

107 192 124

3

2½"

127 212 124

3

3"

142 227 124

4

DN100 DN150 DN200

PN16 and ASME 150

4"

162 247 124

4

6"

218 303 154

8

8"

274 359 219

10

* Please note: 2.4 kg must be added to account for the transmitter.

Sizing information

Litres / sec

m 3 / h

Size

Q min

Q max

Q min

Q max

DN25

1"

0.24

4.89

0.88

17.6

DN32

1¼"

0.40

8.03

1.45

28.9

DN40 DN50 DN65 DN80

1½"

0.54

10.75

1.94

38.7

2"

0.87

17.33

3.12

62.4

2½"

1.56

31.11

5.61

112.00

3"

2.27

45.28

8.17

163.00

DN100 DN150 DN200

4"

4.00

80.00

14.42

288.00

6"

9.00

186.00

33.96

671.00

8"

17.00

330.00

59.99

1188.00

Please note that Min/Max figures are typical based on reference flow conditions. Actual min/max values will be listed on product label and will be confirmed at time of order.

TI-P309-01 EMM Issue 3

Page 2 of 3

ELM ElectroMagnetic Inductive Flowmeter