Flowmetering Electromagnetic flowmeters 3
Dimensions / weights (approximate in mm and kg)
205
115
108
A
158
D
L
M20 x 1.5
DN
Dimensions
Size
Weight *
D
A
L
DN25
1"
72
158 104
2
3.8 2
DN32
1¼"
82
168 124
2
PN40 and ASME 300
DN40 DN50 DN65 DN80
1½"
92
179 124
2
2"
107 192 124
3
2½"
127 212 124
3
3"
142 227 124
4
DN100 DN150 DN200
PN16 and ASME 150
4"
162 247 124
4
6"
218 303 154
8
8"
274 359 219
10
* Please note: 2.4 kg must be added to account for the transmitter.
Sizing information
Litres / sec
m 3 / h
Size
Q min
Q max
Q min
Q max
DN25
1"
0.24
4.89
0.88
17.6
DN32
1¼"
0.40
8.03
1.45
28.9
DN40 DN50 DN65 DN80
1½"
0.54
10.75
1.94
38.7
2"
0.87
17.33
3.12
62.4
2½"
1.56
31.11
5.61
112.00
3"
2.27
45.28
8.17
163.00
DN100 DN150 DN200
4"
4.00
80.00
14.42
288.00
6"
9.00
186.00
33.96
671.00
8"
17.00
330.00
59.99
1188.00
Please note that Min/Max figures are typical based on reference flow conditions. Actual min/max values will be listed on product label and will be confirmed at time of order.
TI-P309-01 EMM Issue 3
Page 2 of 3
ELM ElectroMagnetic Inductive Flowmeter
Powered by FlippingBook