44

Control systems Electric actuators

Maximum differential pressures in bar (psi) for Class VI shut - off - PTFE Seat (G) Spira - trol - DN15 - DN25 (½" - 1'') - FLOW UNDER

Standard Cage (S) DN15 - DN25 (½" - 1")

Cage Type

Valve size

Kvs

Actuator Type

0.01 - 0.5

1

1.6

2.5

4

Cv

0.012 - 0.58

1.2

1.8

2.9

4.6

Actuator thrust kN (lbf)

N - P

H DN-PH DN-PH DN-PH DN-PH D

1.2 (270) 2.0 (450) 4.0 (900)

AEL71

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

AEL72

AEL73

4.3 40

Standard Cage (S)

Low Noise Cage (P1)

Cage Type

DN15 - DN25 (½" - 1")

Valve size

Kvs

Actuator Type

4.9 - 6.3

7.2

10

11

2.5 - 4 - 6.3 - 10

Cv

5.7 - 7.3

8.3

12

12.7

2.9 - 4.6 - 7.3 - 12

Actuator thrust kN (lbf)

N - P

H DN-PH DN-PH DN-PH DN-PH D

1.2 (270) 2.0 (450) 4.0 (900)

AEL71

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

4.0 (58)

AEL72

AEL73

Note: Maximum differential pressure for saturated steam. Refer to Spirax Sarco for other liquids and gases.

TI-P713-02 CTLS Issue 8

Page 16 of 30

AEL7 Series Electric Linear Actuator