Product Handbook 2026 - Volume 2

Pipeline ancillaries Ball valves

10

Pressure/temperature limits

-29 0 50 100 150 200 260 310

Steam saturation curve

0

10

20

30

40

Pressure bar g

The product must not be used in this region. The product can only be used in this region for short periods of time.

Body design conditions

PN40

40 bar g @ 120 ° C

PMA Maximum allowable pressure

310 ° C @ 0 bar g For continuous operation, the maximum temperature is 260 °C 310 °C is for short periods only

TMA Maximum allowable temperature

-29 ° C

Minimum allowable temperature

PMO Maximum operating pressure for saturated steam service

32 bar g

260 ° C @ 0 bar g

TMO Maximum operating temperature

Minimum operating temperature Note: For lower operating temperatures consult Spirax Sarco. PMX Maximum differential pressure is limited to the PMO Designed for a maximum cold hydraulic test pressure of:

-29 ° C

60 bar g

7.3.185

10.3 188

TI-P133-85 CMGT Issue 3

Page 2 of 9

M21Hi ISO Reduced Bore Ball Valve