Product Handbook 2026 - Volume 2

Steam traps Balanced pressure

8

Pressure/temperature limits (ISO 6552)

A

Steam saturation curve

C

B

D

Pressure bar g

The product must not be used in this region. The product should not be used in this region or beyond its operating range as damage to the internals may occur.

A - B Flanged ASME (ANSI) 300. A - C Flanged EN 1092 PN40. A - D Flanged ASME (ANSI) 150.

Body design conditions

ASME (ANSI) 300

50 bar g @ 50 ° C

PMA Maximum allowable pressure

400 ° C @ 35 bar g

TMA Maximum allowable temperature

-60 ° C

Minimum allowable temperature

PMO Maximum operating pressure for saturated steam service

32 bar g @ 281 °C

5.2.47

281 ° C @ 32 bar g

TMO Maximum operating temperature

Minimum operating temperature 0 ° C BPC32 and BPC32Y product ranges are verified safe for use under full vacuum conditions for integral and welded flanged connections. Note: Please consult Spirax Sarco to confirm full vacuum suitability, for other pipe connections. Designed for a maximum cold hydraulic test pressure of 75 bar g

8.2 66

TI-P005-10 CMGT Issue 4

Page 2 of 5

BPC32F and BPC32YF Carbon Steel Integrally Flanged Balanced Pressure Thermostatic Steam Traps