Product Handbook 2026 - Volume 2

Pipeline ancillaries Ball valves

10

Technical data Flow characteristic

Modified linear

Port

Reduced bore

Leakage test procedure to ISO 5208 (Rate A)/EN 12266-1 (Rate A) Antistatic device (optional) complies with ISO 7121 and BS 5351

Pressure / temperature limits

A

      

 

B

C













Pressure bar g

The product must not be used in this region.

A - B Flanged ASME 300. A - C Flanged ASME 150.

Body design conditions

ASME B 16.34

ASME 150

19 bar g @ 38 °C

PMA Maximum allowable pressure

ASME 300

51 bar g @ 38 °C

ASME 150

70 °C @ 18 bar g

TMA Maximum allowable temperature

ASME 300

70 °C @ 48 bar g

Minimum allowable temperature

-29 °C

ASME 150

19 bar g @ 38 °C

PMO Maximum operating pressure

ASME 300

51 bar g @ 38 °C

ASME 150

70 °C @ 18 bar g

TMO Maximum operating temperature

ASME 300

70 °C @ 48 bar g

Minimum operating temperature

-29 °C

Note: For lower operating temperatures consult Spirax Sarco  PMX Maximum differential pressure is limited to the PMO

ASME 150

28.5 bar g

10.3 320

Designed for a maximum cold hydraulic test pressure of:

ASME 300

76.5 bar g

TI-P133-95 CMGT Issue 4

Page 2 of 9

M40Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN25 to DN200 Flanged ASME 150 and ASME 300