Pipeline ancillaries Ball valves
10
Technical data Flow characteristic
Modified linear
Port
Reduced bore
Leakage test procedure to ISO 5208 (Rate A)/EN 12266-1 (Rate A) Antistatic device (optional) complies with ISO 7121 and BS 5351
Pressure / temperature limits
A
B
C
Pressure bar g
The product must not be used in this region.
A - B Flanged ASME 300. A - C Flanged ASME 150.
Body design conditions
ASME B 16.34
ASME 150
19 bar g @ 38 °C
PMA Maximum allowable pressure
ASME 300
51 bar g @ 38 °C
ASME 150
70 °C @ 18 bar g
TMA Maximum allowable temperature
ASME 300
70 °C @ 48 bar g
Minimum allowable temperature
-29 °C
ASME 150
19 bar g @ 38 °C
PMO Maximum operating pressure
ASME 300
51 bar g @ 38 °C
ASME 150
70 °C @ 18 bar g
TMO Maximum operating temperature
ASME 300
70 °C @ 48 bar g
Minimum operating temperature
-29 °C
Note: For lower operating temperatures consult Spirax Sarco PMX Maximum differential pressure is limited to the PMO
ASME 150
28.5 bar g
10.3 320
Designed for a maximum cold hydraulic test pressure of:
ASME 300
76.5 bar g
TI-P133-95 CMGT Issue 4
Page 2 of 9
M40Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN25 to DN200 Flanged ASME 150 and ASME 300