Product Handbook 2026 - Volume 2

32 14

Pipeline ancillaries HV3 stop valve Ball valves

Pipeline ancillaries Lift check valves 10

LCV7 pressure/temperature limits (continued)

Pressure psi g

0

29

58

87

116

145

174 199

572 482 392 302 212 122 32

E

Steam saturation curve

F

Pressure bar g

The product must not be used in this region.

E - F Flanged JIS/KS 10.

Body design conditions

JIS/KS 10

PMA Maximum allowable pressure

13.7 bar g @ 120 °C

199 psi g @ 248 °F

TMA Maximum allowable temperature

300 °C @ 9.8 bar g

572 °F @ 142 psi g

Minimum allowable temperature

0 °C

32 °F

Flanged JIS/KS 10

PMO Maximum operating pressure for saturated steam service

12.3 bar g

178 psi g

TMO Maximum operating temperature

300 °C @ 9.8 bar g

572 °F @ 142 psi g

Minimum operating temperature Note: For lower operating temperatures consult Spirax Sarco.

0 °C

32 °F

Designed for a maximum cold hydraulic test pressure of:

20 bar g

290 psi g

10.1 12 10.4

TI-P029-16 CMGT Issue 9

Page 8 of 12

LCV3, LCV4, LCV6 and LCV7 Lift Check Valves