Product Handbook 2026 - Volume 2

Pipeline ancillaries Disc, split disc and wafer check valves

10

Pressure/temperature limits

Pressure psi g

0

29

58

87

116

145

428

392

302 212 122 32

Steam saturation curve

Pressure bar g

Body design conditions

PN10

PMA Maximum allowable pressure

10 bar g @ 220 °C

145 psi g @ 428 °F

TMA Maximum allowable temperature

220 °C @ 10 bar g

428 °F @ 145 psi g

Minimum allowable temperature

-254 °C

-425 °F

PMO Maximum operating pressure for saturated steam service

10 bar g

145 psi g

TMO Maximum operating temperature

220 °C @ 10 bar g

428 °F @ 145 psi g

Minimum operating temperature

0 °C

32 °F

Designed for a maximum cold hydraulic test pressure of:

15 bar g

217 psi g

Dimensions/weights (approximate) in mm (inches) and kg (lbs)

B

A

Sanitary clamp Size

SIZE

A

B

Weight

ASME

DIN

ASME

ASME

DIN

½" ¾"

DN15

40 (1.6)

25.0 (0.98)

34.0 (1.34)

0.5 (1.10)

10.5 3

DN20

25 (0.98)

0.6 (1.32) 0.9 (1.98) 1.2 (2.65)

1"

DN25

50.39 (1.98)

50.5 (1.99)

30 (1.2) 35 (1.4)

1½"

DN40

63.91 (2.51)

64.0 (2.52)

2"

DN50

TI-P029-21 CMGT Issue 5

Page 3 of 4

CVS10 Sanitary Check Valve with Metal Seat