Product Handbook 2026 - Volume 2

Steam traps Balanced pressure

8

Pressure/temperature limits (ISO 6552)

Pressure psi g

464

0

145

290

435

580

725

752 572 392 212 32

464

Steam saturation curve

Pressure bar g

The product must not be used in this region. The product should not be used in this region or beyond its operating range as damage to the internals may occur.

A - B Screwed, socket weld, butt weld and flanged ASME 300 A - C Flanged EN 1092 PN40 A - D Flanged JIS / KS 20K

A - E Flanged ASME 150 F - G Flanged JIS / KS 10K

Maximum body design conditions

PN40

PMA Maximum allowable pressure

50 bar g @ 50 °C 725 psi g @ 122 °F

TMA Maximum allowable temperature

400 °C @ 30 bar g 752 °F @ 435 psi g

Minimum allowable temperature

-200 °C

-328 °F

PMO Maximum operating pressure for saturated steam service

32 bar g

464 psi g

TMO Maximum operating temperature

240 °C @ 32 bar g

°F @ psi g

Minimum operating temperature Note: For lower operating temperatures consult Spirax Sarco

0 °C

32 °F

8.2 78

Designed for a maximum cold hydraulic test pressure of

75 bar g

1 087 psi g

TI-P005-05 CMGT Issue 6

Page 2 of 5

IBPS32 Stainless Steel Balanced Pressure Thermostatic Steam Trap with Integral Spiratec Sensor

Powered by