Pipeline ancillaries Separators and insulation jackets
10
Dimensions, weights and volumes approximate in mm (inches), kg (lbs) and litres (gallons)
2 Inspection opening (2" only)
B
A
Separator drain tapping F
G
C Drain E
D
Size 1¼" 1½"
ABCDEFG Weight
Volume
mm, kg and litres
111 156 89 304 12.7 25.4 60
9.0
1.5
2"
146 205 117 397 12.7 25.4 71
17.0
3.2
Size 1¼" 1½"
ABCDEFG Weight
Volume
inches, lbs and gallons
4.37 6.14 3.5 12 ½"
1"
2.36
19.8
0.40
2"
5.75 8.07 4.61 15.6 ½"
1"
2.80
37.5
0.85
7.7.12
Recom mended tightening torques
or mm
Item Size
N m
(lbf ft)
2
2"
46 A/F
M56
150 - 165
(110 - 121)
Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P023-55) supplied with the product. Installation note: Install in a horizontal pipeline with the drain directly below. Note: To ensure that any separated liquid is drained away quickly, a suitable liquid drainer or steam trap must be connected to the drain connection 'E' - consult Spirax Sarco for further details. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product, providing due care is taken.
10.7 13
How to order Example: 1 off 2" Spirax Sarco S12 separator with SG iron body having screwed BSP connections.
TI-P023-25 CMGT Issue 5
Page 3 of 3
S12 SG Iron Separator (Screwed)
Powered by FlippingBook