Pipeline ancillaries Air vents and air eliminators
10
Free discharge capacity For air at 16 °C (61 °F)
Differential pressure psi (x 6.89 = kPa)
1
3
4 6 7
15
29 44 58 73 116 6 4
If the temperature of the air differs from 16 °C (61 °F), the discharge capacity from the graph can be corrected by multiplying it by the following equation: 289 273 + T (T is the actual temperature in °C)
2
1 0.8 0.6 0.2
It may be assumed that the temperature of the air is equal to the temperature of the water.
0.1
Differential pressure bar (x 100 = kPa)
Dimensions/weights (approximate) in mm (inches) and kg (lbs)
A
C
Version
A B C D
Weight
0.7 (1.54) 0.9 (1.98)
B
AE30, AE30A
56 (2.2)
105 (4.13)
10 (0.39)
155 (6.10)
D
AE30B, AE30C
10.11 37
Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P017-08) supplied with the product. Installation note: The automatic air eliminator/air vent should be installed vertically with the inlet at the bottom. We recommend piping the discharge from the air eliminator/air vent to a suitable drainpoint.
How to order Example: 1 off Spirax Sarco ½ " AE30C automatic air eliminator with check valve and lockshield valve screwed BSP.
TI-P017-07 CMGT Issue 15
Page 5 of 6
AE30, AE30A, AE30B and AE30C Automatic Air Eliminators/Air and Gas Vents for Liquid Systems