Steam traps Ball float
8
Dimensions/weights (approximate) in mm and kg Notes: 1. Dimensions in brackets relate to vertical connections only. 2. PN40 face-to-face dimensions are in accordance with EN 26554 (Series 1). Size
PN40 A (A)
ASME 300 A (A)
ASME 150 A (A)
JIS/KS 20K A (A)
B
C
DN15
150 (150)
209 (150)
203 (150)
206 (150)
80
80
DN20
150 (150)
209 (150)
205 (150)
210 (150)
80
80
DN25
160 (160)
212 (160)
208 (160)
210 (160)
115
85
DN40 DN50
230 (230)
327 (230)
321 (230)
322 (230)
130
115
230 (230)
320 (230)
313 (230)
311 (230)
141
123
FT44 DN15 and DN20
FT44V DN25, DN40 and DN50
FT44V DN15 and DN20
FT44 DN25, DN40 and DN50
B
B
(A)
(A)
C
C
A
(F)
F
(D)
F
E
E
D
E
5.5.75
Size PN40 ASM ASME JIS/KS 20K All
PN40 ASME/
All
PN40 ASME/
All
Weight
300 150
JIS/KS
JIS/KS
A A A
A
(A)
B C D D (D)
E F
F (F)
DN15
150 209 203
206
(150) 80 80 215 163 (215) 120 155 103 (155)
10.8
DN20 DN25 DN40 DN50
150 209 205
210
(150) 80 80 225 163 (225) 120 165 103 (165)
10.8
160 212 208
210
(160) 115 85 276 209 (280) 170 215 147 (218)
15.0
230 327 321
322
(230) 130 115 326 248 (337) 200 200 121 (210)
33.0
230 320 313
311
(230) 141 123 332 251 (347) 200 235 154 (250)
34.0
8.5 82
Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-S02-30) supplied with the product. Installation note: The FT44 must be installed with the direction of flow as indicated on the body, and with the float arm in a horizontal plane so that it rises and falls vertically. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product, providing due care is taken.
How to order Example: 1 off Spirax Sarco DN25 FT44-14 ball float steam trap, flanged to EN 1092 PN40 with carbon steel body and cover and thermostatic air vent.
TI-S02-14 CMGT Issue 18
Page 6 of 7
FT44 Carbon Steel Ball Float Steam Traps (DN15 to DN50)
Powered by FlippingBook