Steam traps Inverted bucket
8
Pressure/temperature limits (ISO 6552) - Flanged EN1092-1
Pressure psi g
0
290
580
870
1160
1450
H
G
797 752 572
A
Steam saturation curve
392
212
H
G
32
Pressure bar g
The product must not be used in this region or beyond the parameter of the PMA or TMA of the relative end connection.
* Please note that the PMO (PS) is limited to the maximum D P of the selected IBV.
Body design conditions
PN100
PMA - Maximum allowable pressure
100 bar g @ 50 °C 1450 psi g @ 122 °F
TMA - Maximum allowable temperature
425 °C @ 44.9 bar g 797 °F @ 651 psi g
5.6.41
Minimum allowable temperature
-29 °C
-20.2 °F
A-G-G
PN100
Maximum operating pressure for saturated steam service
* PMO (PS) -
66 bar g
957 psi g
Maximum operating temperature for saturated steam service
TMO (TS)
283 °C @ 44.9 bar g 541 °F @ 651 psi g
Designed for a maximum cold hydraulic test pressure of:
143 bar g
2074 psi g
PMA - Maximum allowable pressure
63 bar g @ 50 °C 914 psi g @ 122 °F
8.6 38
TMA - Maximum allowable temperature
425 °C @ 28.3 bar g 797 °F @ 410 psi g
Minimum allowable temperature
-29 °C
-20.2 °F
A-H-H
PN63
Maximum operating pressure for saturated steam service
* PMO (PS) -
44 bar g
638 psi g
Maximum operating temperature for saturated steam service
TMO (TS)
257 °C @ 28.3 bar g 495 °F @ 410 psi g
Designed for a maximum cold hydraulic test pressure of:
90 bar g
1305 psi g
TI-P067-10 CMGT Issue 4
Page 6 of 17
IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap
Powered by FlippingBook