Product Handbook 2026 - Volume 2

Steam traps Inverted bucket

8

Pressure/temperature limits (ISO 6552) - Screwed, Socket weld and Flanged EN1092-1 (continued)

L K

A

Steam saturation curve

L

K

Pressure bar g

The product must not be used in this region or beyond the parameter of the PMA or TMA of the relative end connection. * Please note that the PMO (PS) is limited to the maximum D P of the selected IBV.

PMA - Maximum allowable pressure

25 bar g @ 50 °C

TMA - Maximum allowable temperature

425 °C @ 11.2 bar g

Minimum allowable temperature

-46 °C

A-K-K

PN25

* PMO (PS) - Maximum operating pressure for saturated steam service

19 bar g

TMO (TS) - Maximum operating temperature for saturated steam service

212 °C @ 11.6 bar g

Designed for a maximum cold hydraulic test pressure of:

35.7 bar g

PMA - Maximum allowable pressure

16 bar g @ 50 °C

TMA - Maximum allowable temperature

425 °C @ 7.1 bar g

Minimum allowable temperature

-46 °C

A-L-L

PN16

8.6 57

* PMO (PS) - Maximum operating pressure for saturated steam service

12 bar g

TMO (TS) - Maximum operating temperature for saturated steam service

191 °C @ 7.4 bar g

Designed for a maximum cold hydraulic test pressure of:

22.8 bar g

TI-P067-13 CMGT Issue 4

Page 7 of 17

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap