Steam traps Inverted bucket
8
How to order 1 off Spirax Sarco IBV - C-LF2 - 116 - 110 - 3" - Flanged ASME Class 300 inverted bucket vertical steam trap having a carbon steel body and cover with stainless steel internals. The following will be supplied, if specified, at the time of order placement: 1. A special name-plate when a U-STAMP has been specified.
Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions supplied with the product. Installation note
The trap must be installed below the drain point with the body upright in a vertical position, the cover at the top and the inlet connection at the bottom; this orientation will ensure that the bucket mechanism will rise and fall vertically without any friction. It is recommended that a strainer is installed upstream of the IBV to protect it from contamination. To permit safe inspection for cleaning or maintenance purpose it is again recommended that suitable shut-off valves are installed upstream and downstream of the IBV application. It needs to be appreciated that there is blast discharge with this device, consequently the downstream accessories, if any, should be installed at a minimum distance of 1 m from the IBV. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken.
8.6 66
TI-P067-13 CMGT Issue 4
Page 16 of 17
IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap