Steam traps Thermodynamic
8
Capacities (in accordance with ISO 7842)
Differential pressure psi (x 6.9 = kPa)
116 145
290 435 580 725
1450
3626
1102 881
Cold water capacity
661
Hot water capacity
440
220
132
Differential pressure bar (x 100 = kPa)
pressure
cold water kg/h (lb/h)
Hot condensate kg/h (lb/h)
pressure
cold water kg/h (lb/h)
Hot condensate kg/h (lb/h)
bar g
psi g
bar g
psi g
8
138
116
98 (217)
71 (156)
2000
329 (725)
221 (487)
5.7.67
17
155
250
136 (300)
96 (212)
2250
346 (762)
231 (510)
34
172
500
183 (403)
127 (280)
2500
361 (796)
241 (532)
52
190
750
217 (478)
149 (329)
2750
376 (829)
251 (553)
69
207
1000
245 (540)
167 (369)
3000
390 (860)
259 (572)
86
224
1250
269 (594)
183 (404)
3250
404 (890)
268 (591)
103
241
1500
291 (641)
197 (434)
3500
416 (918)
276 (608)
121
250
1750
311 (685)
209 (461)
3625
423 (932)
280 (617)
8.7 102
TI-P150-11 CMGT Issue 6
Page 4 of 6
TD120M High Pressure Thermodynamic Steam Trap with Replaceable Seat