Dimensions/weights (approximate) in mm (inches) and kg (lbs)

Withdrawal distance F

C

A

Size

A B C D E

F Weight

½" ¾"

80 (3.1) 85 (3.3)

92 (3.6) 100 (3.9)

92 (3.6) 92 (3.6)

52 (2.1) 47 (1.9)

20 (0.8) 20 (0.8)

51 (2.0) 51 (2.0)

2.08 (4.6) 2.43 (5.4)

1"

D

B

Withdrawal distance E

Capacities

Differential pressure psi (x 6.9 = kPa)

435 725

20 29

44 58 73

145

290

580 899

5.7.71

1102 882 661 441

220

110 88 66 44

8.7 108

Differential pressure bar (x 100 = kPa) Minimum operating pressure 8 bar for the TD62LM

Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P015-04) supplied with the product. Installation note: Preferably install in horizontal pipelines with the insulating cover uppermost although it can be fitted in other positions. After 24 hours in service the cover nuts should be checked for tightness. Disposal The product is recyclable no ecological hazard is anitcipated with the disposal of this product, providing due care is taken.

How to order Example: 1 off Spirax Sarco ½ " TD62LM thermodynamic steam trap with integral strainer having screwed NPT connections, suitable for steam main drainage. An aluminium insulating cover shall be fitted as standard.

TI-P068-08 CMGT Issue 13

Page 4 of 5

TD62LM and TD62M Thermodynamic Steam Traps with replaceable seats (Screwed / Socket Weld)