UK Product Handbook 2026 - Volume 2

Steam traps Swivel connectors and traps

8

ASME Class 900 Pressure/temperature limits (ISO 6552)

Pressure psi g

1363

0 145 290 435 580 725 870 1015 1160 1305 1450 1595 1740 1885 2030 2175 2320 500

932

The product must not be used in this region

842

450

752

400

662

350

584.6

307

572

300

482

250

392

200

Steam saturation curve

302

150

212

100

122

50

32

0

8.9 15

0

10

20

30 40 50

60

70

80 90 100 110 120 130 140 150 160

94

Pressure bar g

Notes: - If flange connections are fitted then these will limit the maximum design conditions of the pipeline connector. - The maximum operating limits of the complete assembly will be dictated by the steam trap of choice. Reference the specific steam trap Technical Information sheet for its maximum pressure / temperature limitations.

Body design conditions

ASME Class 900

PMA Maximum allowable pressure

149.1 bar g @ 38 °C

2163 psi g @ 100 °F

TMA Maximum allowable temperature

482 °C @ 86 bar g

900 °F @ 1245 psi g

Minimum allowable temperature

-46°C

-50.8 °F

PMO Maximum operating pressure for saturated steam service

94 bar g @ 307 °C

1363 psi g @ 584.6 °F

TMO Maximum operating temperature

482 °C @ 86 bar g

900 °F @ 1245 psi g

Minimum operating temperature

0 °C

32 °F

Designed for a maximum cold hydraulic test pressure of

224 bar g

3249 psi g

The PC90 is suitable for full vacuum condition. * Note: For lower operating temperatures consult Spirax Sarco

TI-P806-01 CMGT Issue 3

Page 3 of 7

PC90 4-Bolt Pipeline Connector

Powered by