Available types For piping installation diagrams see TI-F01-37. Flow direction Type Description Left to right PC33

1 stop valve + upstream line drain for a BDV1 or BDV2 and trap vent connection for BDV2

Right to left Universal - Both: left to right or right to left

PC34 PC30

1 stop valve

1 stop valve + upstream line drain connection either side of the body for BDV1 or BDV2. It is necessary to plug one connection. This must always be the top connection.

PC35

Pressure/temperature limits

Steam saturation curve

Pressure bar g

The product must not be used in this region.

Notes: 1. If flange connections are fitted then these will limit the maximum design conditions of the pipeline connector. 2. The maximum operating limits of the complete assembly will be dictated by the steam trap of choice. Reference the specific steam trap technical information sheet for its 'Pressure / temperature limits'.

Body design conditions

ASME class 600

99.3 bar g @ 38 ° C

PMA Maximum allowable pressure

425 ° C @ 56 bar g

TMA Maximum allowable temperature

PMO Maximum operating pressure for saturated steam service

62 bar g

425 ° C @ 56 bar g

TMO Maximum operating temperature

8.9 20

Product is safe for use under full vacuum conditions Designed for a maximum cold hydraulic test pressure of

150 bar g

Kv value: Both the DN15 and DN20 have a Kv value of Kv 1.8 For conversion:

Cv (UK) = Kv x 0.963 Cv (US) = Kv x 1.156