Product Handbook 2026 - Volume 2

Steam traps Swivel connectors and traps

8

Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P127-02) supplied with the product. Installation note: The UBP32 can be installed on any pipeline connector in any plane. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken.

Spare parts The UBP32 is a sealed non-maintainable trap unit. No internal spares are available. The spares which are available are shown in solid outline. Parts shown in a grey line are not available as spares.

Available spares Connector screws

10

Complete UBP32 trap unit inclusive of gaskets and connector screws ( 10 )

How to order spares Always order spare parts by using the description given in the column headed 'Available spares' and state the size, Model No. and pressure rating of the trap. Example: 2 - Connector screws for a UBP32 sealed balanced pressure thermostatic steam trap.

10

UBP32 trap unit and gaskets

Recommended tightening torques

8.9 53

or mm

Item

N m

(ft lbf)

10

16 "

30 - 35

(22 - 26)

9 /

TI-P127-01 CMGT Issue 10

Page 5 of 5

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with Pipeline Connectors

Powered by