Steam traps Swivel connectors and traps

8

H, H DSH, V, V DSH H, H DSH, V, V DSH H, H DSH, V, V DSH H, H DSH, V, V DSH

Double Block and Bleed Upstream Vertical (DBB USV)

Double Block and Bleed Upstream Vertical Downstream Horizontal (DBB USV DSH)

The DBB (Double Block and Bleed) variation provides enhanced safety and possibility to drain the steam trapped between the isolation valves by adding a T shaped connection. The STS17.2 trapping solution incorporates Spirax Sarco quickfit technology, which allows speedy trap maintenance. The following swivel connector steam traps (sold separately) can be used with this pipeline connector enabling it to be tailored to suit any application: - UTD26 and UTD52 thermodynamic steam traps. - UBP32 balanced pressure steam trap.

8.9 97

- USM bimetallic steam trap. - UFT32 ball float steam trap. - UIB30 and UIB30H inverted bucket steam traps.

Standards These products fully comply with the requirements of the European Pressure Equipment Directive 2014/68/EU. Certification These products are available with certification to EN 10204 3.1. Note: All certification/inspection requirements must be stated at the time of order placement. For other certification contact Spirax Sarco.

TI-P128-22 CMGT Issue 14

Page 3 of 15

STS17.2 Stainless Steel Compact Pipeline Connector Steam Trapping Station