Steam traps Manifolds and insulation jackets
8
Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions supplied with the product. General These manifolds have been designed for vertical installation. The back is provided with threaded connections M12 for ease of installation by attaching to a supporting structure.
Spacer
M12 nut
Installation view from above
2" (51 mm)
M12 stud
Structural steelwork
Mounting kits The manifold is generally conveniently attached to the structural steelwork supporting the plant. For ease of insulation it is recommended that spacers are fitted to give the manifold a stand-off of at least 2" (51 mm). For convenience the following set of mounting kit is available: - A single set comprising 2 off each stud, nut and spacer suitable for installing one MSC-210.
After installation it is recommended that the manifold is insulated to minimise heat losses and to protect personnel from burn risks.
Condensate collection duty The recommended installation is with the condensate outlet at the top. The bottom of the manifold should be fitted with a stop valve for blowdown purposes. Again, we recommend that a diffuser is fitted.
How to order Example: 1 off Spirax Sarco MSC-210 steam condensate collection manifold, with 8" (203 mm) pitch, Dual Certified ASTM A105N/350LF2 forged carbon steel body with 4 x ¾" socket weld connections to ASME B 16.11 Class 3000. Complete with EN 10204 3.1 certification. Spare parts The spare parts available are detailed below. Available spares Mounting kit (See above) - A single set comprising 2 off each stud, nut and spacer suitable for installing one MSC-210
8.10 9
TI-P115-01 CMGT Issue 3
Page 3 of 3
MSC-210 Long Pitch Manifold for Condensate Collection