Product Handbook 2026 - Volume 2

Condensate pumps Mechanical pumps and pumps traps

9

Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without notice. © Copyright 2018

TI-P136-07 CMGT Issue 6

IJ-MFP Insulation Jackets for MFP Automatic Pumps

Description A range of tailored insulation jackets for fitting to automatic pumps type MFP.

Sizes Jacket type Pump size

Pump type

DN25

MFP14

DN40

MFP14

6

DN50

MFP14, MFP14S and MFP14SS

IJ-MFP

* Pre date code A05: * MFP14, MFP14S and MFP14SS * Post date code A05: * MFP14

DN80 x DN50

3

1

Limiting conditions Maximum service temperature

6.1.31

220 ° C

0.044 W/m K at 100 ° C

Insulation thermal conductivity

Maximum weight

4.5 kg

5

Materials No. Part

Material

9.1 34

1 2 3 4 5 6

Jacket covering

Silicone coated glass fibre

Insulation

Mineral fibre

Stitching

Polyester cotton

Draw cord

Nylon

Fastening

Velcro

Label

Nylon

4

2

1369050/6

Powered by