Product Handbook 2026 - Volume 2

Condensate pumps Electric pumps

9

Sizing and selection – Duty/assist fixed speed pumps (50 Hz ) Information required for sizing and selection: 1. Maximum load at which condensate returns to the receiver in m 3 /hr. 2. Total pumping delivery head, including lift and friction losses in pipework and fittings. Sizing and selection For correct selection plot the condensate return rate to be handled against the total head required (static + friction) and select the appropriate unit. If selection is borderline then select the next largest unit. Selection example: The condensate return rate is 3 m 3 /hr and the total head required is 30 m with a carbon steel frame. Draw a horizontal line from the known 30 m head required until it intersects with the vertical line that represents the 3 m 3 /hr of condensate to be handled. For this example the selection would be a CRU200-2D-CM34-CS.

CRU200

CRU500

45

45

40

40

4D-CM103

4D-CM103

35

35

30

30

6.2.20

2D-CM34

25

25

5D-CM152

4D-CM102

20

20

4D-CM102

9.2 5

15

15

2D-CM33

10

10

5D-CM151

4D-CM101

4D-CM101

5

5

0

0

0

2

4

6

8

10

12

14

16

18

20

Condensate to be handled (m 3 /hr)

Example

Not selectable

TI-P681-06 CMGT Issue 2

Page 5 of 6

CRU 200 and 500 Series Condensate Recovery Units (fixed speed pumps)

Powered by