Product Handbook 2026 - Volume 2

Product limitations (continued) Pipeline ancillaries Bellows sealed stop valves

10

BSA6T and BSA64

Pressure psi g

0

145

290

435

580

752 572 392 212 32 -20

Steam saturation curve

Pressure bar g

The product must not be used in this region.

Note: ∆PMX Maximum differential pressure is limited to the PMO. Body design conditions

PN40

PMA Maximum allowable pressure

40 bar g @ 50 °C (580 psi g @ 122 °F)

TMA Maximum allowable temperature

400 °C @ 25 bar g (752 °F @ 363 psi g)

Minimum allowable temperature

-10 °C (14 °F)

Metal seat

29.8 bar g @ 236 °C (432 psi g @ 457 °F)

Maximum operating pressure for saturated steam service

PMO

Soft seat

27.0 bar g @ 230 °C (391 psi g @ 446 °F)

Metal seat

400 °C @ 25.6 bar g (752 °F @ 371 psi g)

TMO Maximum operating temperature

Soft seat

230 °C @ 27.0 bar g (446 °F @ 391 psi g)

Minimum operating temperature

-10 °C (14 °F)

On/off function

Limited to the PMO

∆PMX Maximum differential pressure

DN15 - DN80 (½" - 3")

2 bar (29 psi)

Throttling function

DN100 (4")

1.5 bar (22 psi)

Designed for a maximum cold hydraulic test pressure of:

60 bar g (870 psi)

Maximum permissible differential pressure in throttling function: DN15 - DN80 (½" - 3") 2.0 bar (29 psi) DN100 (4") 1.5 bar (22 psi)

Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-P137-02) supplied with the product. Installation note Install in the direction of flow given by the arrow on the body with the handwheel in a suitable position. Disposal These products are recyclable. No ecological hazard is anticipated with the disposal of these products, providing due care is taken.

10.1 22

TI-P137-18 CMGT Issue 15

Page 16 of 17

BSAT and BSA Bellows Sealed Stop Valves

Powered by