Pipeline ancillaries Separators and insulation jackets
10
Dimensions/weights/volume (approximate) in mm, kg and litres
Size
A
B
C Weight
Volume
DN15
294
204
150
4.14
1.26
DN20
347
212
146
5.1
1.56
DN25
386
260
171
8
4.36
DN32
440
274
195
9.7
5.16
A
DN40 DN50 DN65 DN80 DN100
508
310
208
13
8.75
558
310
208
15.1
9.8
638
420
252
30
14
C
735
489
332
46
31
795
574
337
64
48
B
Safety information, installation, and maintenance For full details see the Installation and Maintenance Instructions (IM-P750-02) supplied with the product. Installation note Install in a horizontal pipeline with the drain directly below.
7.7.46
To ensure that any separated liquid is drained quickly, a suitable steam trap/liquid drainer must be connected to the drain connection. For those steam systems where air can be present, air can collect in the upper portion of the separator. In this situation a suitable air vent should be connected to the air vent connection. If an air vent is not being fitted, then the connection must have the plastic transit protection plug removed and must have a stainless- steel class 3 000 lb plug fitted. Disposal The product is recyclable. No ecological hazard is anticipated with disposal providing due care is taken.
How to order Example: 1 off Spirax Sarco DN20 S8F separator with an austenitic stainless-steel body flanged to EN 1092 PN16.
10.7 43
TI-P750-01 CMGT Issue 1
Page 3 of 3
S8F Austenitic Stainless Steel Separator Food +