UK Product Handbook 2026 - Volume 2

Pipeline ancillaries Separators and insulation jackets

10

Dimensions/weights/volume (approximate) in mm, kg and litres

Size

A

B

C Weight

Volume

DN15

294

204

150

4.14

1.26

DN20

347

212

146

5.1

1.56

DN25

386

260

171

8

4.36

DN32

440

274

195

9.7

5.16

A

DN40 DN50 DN65 DN80 DN100

508

310

208

13

8.75

558

310

208

15.1

9.8

638

420

252

30

14

C

735

489

332

46

31

795

574

337

64

48

B

Safety information, installation, and maintenance For full details see the Installation and Maintenance Instructions (IM-P750-02) supplied with the product. Installation note Install in a horizontal pipeline with the drain directly below.

7.7.46

To ensure that any separated liquid is drained quickly, a suitable steam trap/liquid drainer must be connected to the drain connection. For those steam systems where air can be present, air can collect in the upper portion of the separator. In this situation a suitable air vent should be connected to the air vent connection. If an air vent is not being fitted, then the connection must have the plastic transit protection plug removed and must have a stainless- steel class 3 000 lb plug fitted. Disposal The product is recyclable. No ecological hazard is anticipated with disposal providing due care is taken.

How to order Example: 1 off Spirax Sarco DN20 S8F separator with an austenitic stainless-steel body flanged to EN 1092 PN16.

10.7 43

TI-P750-01 CMGT Issue 1

Page 3 of 3

S8F Austenitic Stainless Steel Separator Food +