UK Product Handbook 2026 - Volume 2

Steam traps Thermodynamic

8

Pressure/temperature limits

     

A

Steam saturation curve

B

 C













Pressure bar g

This product is not designed for operation above 16 bar g.

Body design conditions

PN25

PMA Maximum allowable pressure

25 bar g @ 300°C

TMA Maximum allowable temperature

300°C @ 25 bar g

Minimum allowable temperature

0 °C

PMO Maximum operating pressure for saturated steam service

16 bar g

ΔPMN Minimum differential pressure for correct operation

0.2 bar g

PMOB Maximum operating backpressure should not exceed 80% of the inlet pressure under any conditions otherwise the trap may not shut off. TMO Maximum operating temperature

300°C @ 16 bar g

Minimum operating temperature Note: For lower operating temperatures consult Spirax Sarco

0 °C

Designed for a maximum cold hydraulic test pressure of:

38 bar g

Capacities

 



8.7 4



     

 

   





Differential pressure bar (x 100 = kPa)

TI-P151-02 CMGT Issue 4

Page 2 of 4

TD16 Thermodynamic Steam Trap