Steam traps Thermodynamic
8
Dimensions/weights (approximate) in mm and kg Size A B C C1
D
E
E1
F
Weight
½" L and LA
78
57
41
52
59
20
38
90
0.80
½" H and HA
78
57
41
57
59
41
38
90
0.85
¾" L and LA
90
57
44
52
65
20
38
105
1.00
A B
E1 Withdrawal distance
Withdrawal distance E
C1
C
F Withdrawal distance
D
Safety information, installation and maintenance For full details see the Installation and Maintenance Instructions (IM-F01-30) supplied with the product. Installation note The ITD32 should be installed in horizontal pipework with a small drop leg preceding it. The sensor must be positioned directly below the trap body. Maintenance note It is recommended that new gaskets and spares are used whenever maintenance is undertaken. Maintenance may be completed with the trap in the pipeline. Disposal This product is recyclable. No ecological hazard is anticipated with the disposal of this product providing due care is taken.
5.7.11
How to order Example: 1 off Spirax Sarco ½" ITD32L thermodynamic steam trap having an integral Spiratec sensor: - WLS1 to identify waterlogging and steam wastage or - SS1 for steam leakage only. Sensors are to be compatible with Spiratec indicators, automatic monitors and test points: - R1 (single trap) remote test point - R1C (single trap) automatic steam trap monitor with PNP/NPN output where appropriate - R12 (12 trap) remote test point - R16C (16 traps) automatic steam trap monitor - Type 30 hand held indicator
8.7 14
TI-P614-01 CMGT Issue 4
Page 4 of 5
ITD32 Thermodynamic Steam Trap with Integral Spiratec Sensor
Powered by FlippingBook